Physiotrex Logo - Maktrex International
PHYSIOTREX Clinical Physiotherapy Equipment
Direct Factory Support: +91-7053005400 / +91-8851447406
PHYSIOTREX TENS 4 Channel Manual NMS - Physiotrex Clinical Equipment
SKU: MTI46693 • Electrotherapy

PHYSIOTREX TENS 4 Channel Manual NMS

Portable transcutaneous nerve stimulation for analgesia

₹3,500 ₹3,600 Save 3%
In Stock • Inclusive of GST Free Pan-India Insured Freight • 1-Year Comprehensive Replacement Warranty

Availability: In Stock — Ready for Dispatch

Dispatch Facility: Shahdara, Delhi-110032 (Dispatches within 24-48 hours)

Warranty: 1-Year Comprehensive Factory Replacement & On-Site Support

Manual Tactile Parameter Controls: Precise analog rotary potentiometers allow direct, incremental adjustments of pulse rate, pulse width, and output amplitude
Order Direct • Add to Cart / Hotline More in Electrotherapy
Regulated Medical Device (YMYL Compliant) CDSCO Form MD-42 Licensed
  • Quality Management: ISO 9001:2015 Certified System (Certificate No. 24EQCN62)
  • Safety Directives: European CE Medical Electrical Safety Compliant (CE-16198)
  • Manufacturing Origin: Direct from Maktrex International engineering facility, Shahdara, Delhi-110032
  • Direct Warranty: 1-Year Comprehensive Factory Replacement & Calibration Guarantee
  • Practitioner Advisory: Medically reviewed for clinical physiotherapy & hospital rehabilitation workflows

Product Overview & Clinical Applications

Manual Tactile Parameter Controls: Precise analog rotary potentiometers allow direct, incremental adjustments of pulse rate, pulse width, and output amplitude ### Clinical Technical Highlights Quad-channel precision output enabling comprehensive multi-nerve stimulation and large-muscle group protocols. Combined TENS (Transcutaneous Electrical Nerve Stimulation) and Muscle Stimulator modality for integrated Physical Modality Modality and muscle re-education. Optimized for clinical precision under model series MTI46693. PHYSIOTREX TENS 4 Channel Manual NMS (SKU: MTI46693) is a professional clinical rehabilitation modality engineered by Physiotrex for physiotherapy clinics, rehabilitation hospitals, and physical recovery departments. Designed specifically for specialized electrotherapy applications, this system delivers calibrated therapeutic performance adhering to modern physiotherapy standards and clinical safety protocols. Clinical Indications: Recommended for Chronic and acute pain relief (Musculoskeletal, Post-Traumatic, Arthritic), Post-surgical incision discomfort, Sciatica, radiculopathy, and peripheral nerve neuropathic pain. The unit allows physiotherapists and certified clinicians to administer customized treatment protocols based on patient-specific assessments, ROM constraints, and clinical healing stages. Key Engineering Features: Built with 4 Independent Treatment Channels: Features 8-electrode output capacity with dedicated rotary dials for each channel, enabling multi-site or multi-patient care, Microprocessor-controlled clinical precision for hospital and OPD rehabilitation centers, ISO 9001:2015 & CE certified medical-grade build with heavy-duty safety protection, Ergonomic clinical interface with preset therapy protocols and digital timer control. Constructed with medical-grade materials, precision-calibrated components, and durable patient-contact interfaces engineered for high-throughput OPD environments requiring continuous daily operation, durability, and reliable clinical outcomes. Quality Assurance & Clinical Support: Manufactured under stringent quality control protocols, each unit undergoes multi-point inspection before dispatch. Backed by Physiotrex manufacturer warranty, certified technical service, and pan-India direct support.

Clinical Safety Guidelines & Absolute Contraindications

This medical rehabilitation modality must be configured and administered under the clinical guidance of a licensed physiotherapist (BPT/MPT) or medical specialist.

  • Contraindications: Patients with active cardiac pacemakers, implanted cardioverter defibrillators (ICD), or active deep vein thrombosis (DVT).
  • Precautions: Avoid direct application across the carotid sinus, active neoplastic/malignant areas, or during first-trimester pregnancy without obstetric clearance.
  • Dosage Titration: Always start electrical or acoustic output at zero and increase according to verified clinical dosage protocols.

Key Clinical Features

  • 4 Independent Treatment Channels: Features 8-electrode output capacity with dedicated rotary dials for each channel, enabling multi-site or multi-patient care
  • Microprocessor-controlled clinical precision for hospital and OPD rehabilitation centers
  • ISO 9001:2015 & CE certified medical-grade build with heavy-duty safety protection
  • Ergonomic clinical interface with preset therapy protocols and digital timer control

Clinical Governance & Medical Compliance

Intended Use & Target User

Transcutaneous electrical nerve stimulation for non-invasive symptomatic relief of acute and chronic intractable pain via the Gate Control Theory.

Target Professional: Licensed Physiotherapists (BPT/MPT), Sports Medicine Specialists, and Rehabilitation Professionals.

Clinical Indications

  • Chronic and acute pain relief (Musculoskeletal, Post-Traumatic, Arthritic)
  • Post-surgical incision discomfort
  • Sciatica, radiculopathy, and peripheral nerve neuropathic pain

Absolute Contraindications

  • Active cardiac pacemakers or implanted electronic devices (for electro-modalities)
  • First trimester pregnancy (direct application)
  • Active neoplastic areas or malignancy
  • Severe deep vein thrombosis (DVT)
  • Application across the thorax or heart
  • Trans-cerebral application

Clinical Precautions

  • Monitor skin integrity and patient comfort during and after treatment
  • Verify dosage parameters prior to therapy delivery
  • Avoid usage on open wounds or infected skin
  • Avoid usage in patients with diminished thermal/cutaneous sensitivity
  • Do not place directly over carotid sinus or eyes

Scientific Evidence & Regulatory Status

Peer-Reviewed Reference Evidence

  • [1] Melzack R & Wall PD: Pain Mechanisms: A New Theory (Gate Control Theory)
  • [2] Sluka KA: Mechanisms and Evidence of TENS in Pain Modulation
  • [3] Cochrane Review: Transcutaneous Electrical Nerve Stimulation for Chronic Pain

Regulatory Status

CDSCO Form MD-42 Licensed Manufacturer; ISO 9001:2015 Certified Quality System.

Technical Hardware & Clinical Specifications

Manufacturer Verified Technical Parameters for PHYSIOTREX TENS 4 Channel Manual NMS (Model: MTI46693)
Brand Physiotrex (Maktrex International)
Model / SKU MTI46693
Product Classification Clinical Therapy Machinery — 4-Channel Transcutaneous Nerve Stimulator (TENS)
Primary Build Material Shock-Resistant Medical ABS Enclosure + Carbon Silicone Pads
Timer Configuration No Digital Timer (Continuous Manual Rotary Session Control)
Power Source 220V–240V AC, 50Hz Mains Powered
Warranty Status 1-Year Comprehensive Factory Warranty
Payment Option Prepaid (2% Extra Discount) & Cash on Delivery (COD) Available
Quality Standards ISO 9001:2015 & CE Certified (Medical Directive Compliance)
Channel Count 4 Channels (8 Electrodes)
Pulse Frequency / Rate 1 Hz - 150 Hz Variable Step Control
Pulse Width / Duration 50 µs - 400 µs Microsecond Adjustable
Therapy Waveforms Asymmetrical Biphasic, Galvanic, Interrupted Galvanic, Surged Faradic
Therapy Modes Continuous, Burst (2 Hz), Pulse Width Modulation, Frequency Modulation
Operating Voltage 220V - 240V AC, 50 Hz (Mains Powered / Internal Fuse)
Output Intensity 0 - 80 mA Adjustable per Channel with Independent Knobs
Surge Duration 1 - 10 Seconds Adjustable Surge Faradic Cycle
Rest Period 1 - 10 Seconds Rest Cycle
Safety Features Zero Start Safety Interlock, Output Circuit Breaker
Factory Warranty 1-Year Comprehensive Factory Warranty
Dispatched From Central Biomedical Dispatch Facility, Shahdara, Delhi-110032
Country of Origin India

Related Electrotherapy Equipment