Physiotrex Logo - Maktrex International
PHYSIOTREX Clinical Physiotherapy Equipment
Direct Factory Support: +91-7053005400 / +91-8851447406
PHYSIOTREX MS-10 2 Channel Electric Muscle Stimulator & Diagnostic Modality Unit for Physiotherapy - Physiotrex Clinical Equipment
SKU: MTI22448 • Muscle Therapy

PHYSIOTREX MS-10 2 Channel Electric Muscle Stimulator & Diagnostic Modality Unit for Physiotherapy

Clinical-grade physiotherapy & rehabilitation equipment

₹3,999 ₹7,200 Save 44%
In Stock • Inclusive of GST Free Pan-India Insured Freight • 1-Year Comprehensive Replacement Warranty

Availability: In Stock — Ready for Dispatch

Dispatch Facility: Shahdara, Delhi-110032 (Dispatches within 24-48 hours)

Warranty: 1-Year Comprehensive Factory Replacement & On-Site Support

Multi-Waveform Clinical Engine: Delivers Plain Galvanic, Interrupted Galvanic, Surged Faradic, and Tetanic currents for both diagnostic charting and active ther
Order Direct • Add to Cart / Hotline More in Muscle Therapy
Regulated Medical Device (YMYL Compliant) CDSCO Form MD-42 Licensed
  • Quality Management: ISO 9001:2015 Certified System (Certificate No. 24EQCN62)
  • Safety Directives: European CE Medical Electrical Safety Compliant (CE-16198)
  • Manufacturing Origin: Direct from Maktrex International engineering facility, Shahdara, Delhi-110032
  • Direct Warranty: 1-Year Comprehensive Factory Replacement & Calibration Guarantee
  • Practitioner Advisory: Medically reviewed for clinical physiotherapy & hospital rehabilitation workflows

Product Overview & Clinical Applications

The PHYSIOTREX MS-10 2 Channels Electric Muscle Stimulator Diagnostic Modality Unit is a physiotherapy electrotherapy device designed for electrical muscle stimulation and related therapeutic applications, subject to the unit's actual functions and manufacturer specifications. It is a suitable equipment option to consider for physiotherapy clinics, rehabilitation centres, hospitals, and professional therapy facilities. Electrical muscle stimulation uses controlled electrical impulses delivered through electrodes to stimulate targeted muscles or nerves. Depending on the device's available modes and settings, electrical stimulation may be incorporated into selected physiotherapy and rehabilitation programs under the supervision of a qualified healthcare professional. Featuring a 2-channel configuration, the PHYSIOTREX MS-10 is designed to provide two electrical output channels. The practical applications and whether the channels can operate independently or simultaneously should be confirmed against the manufacturer's technical documentation. This electric muscle stimulator can be considered by physiotherapists seeking electrotherapy equipment for clinical practice, muscle stimulation procedures, and appropriate rehabilitation protocols. The device's diagnostic modality functions, if included, should be verified with the supplier before purchase to ensure the equipment meets the intended clinical requirements. The PHYSIOTREX MS-10 is relevant to healthcare providers looking to expand their range of physiotherapy modalities and electrical stimulation equipment. It can be incorporated into a broader treatment approach that may include therapeutic exercises and other rehabilitation interventions, according to individual assessment and clinical judgment. Whether you are equipping a new physiotherapy clinic or upgrading existing electrotherapy equipment, the PHYSIOTREX MS-10 2 Channel Electric Muscle Stimulator offers a product option for professional physiotherapy environments. For safe and effective use, follow the manufacturer's instructions, verify electrode placement and available treatment modes, and ensure that the device is operated by appropriately trained personnel.

Clinical Safety Guidelines & Absolute Contraindications

This medical rehabilitation modality must be configured and administered under the clinical guidance of a licensed physiotherapist (BPT/MPT) or medical specialist.

  • Contraindications: Patients with active cardiac pacemakers, implanted cardioverter defibrillators (ICD), or active deep vein thrombosis (DVT).
  • Precautions: Avoid direct application across the carotid sinus, active neoplastic/malignant areas, or during first-trimester pregnancy without obstetric clearance.
  • Dosage Titration: Always start electrical or acoustic output at zero and increase according to verified clinical dosage protocols.

Key Clinical Features

  • Brand: PHYSIOTREX
  • Model: MS-10
  • Product Type: Electric muscle stimulator and physiotherapy modality unit
  • Channel Configuration: 2 channels
  • Primary Application: Electrical muscle stimulation for appropriate physiotherapy applications
  • Physiotherapy Use: Designed for consideration in professional therapy and rehabilitation settings
  • Rehabilitation Support: May be incorporated into suitable muscle stimulation and rehabilitation programs
  • Clinical Applications: Relevant to physiotherapy clinics, hospitals, and rehabilitation centres
  • Diagnostic Modality: Confirm the specific diagnostic functions and capabilities with the manufacturer
  • Treatment Customisation: Verify available stimulation modes, intensity controls, pulse settings, and treatment parameters
  • Professional Operation: Use according to manufacturer instructions and qualified clinical guidance
  • Specification Check: Confirm output characteristics, included accessories, and warranty details before ordering

Clinical Governance & Medical Compliance

Intended Use & Target User

Galvanic and surged faradic electrical muscle stimulation for neuromuscular re-education, treatment of denervated muscles (Bell’s Palsy, radial/peroneal nerve palsy), and prevention of disuse atrophy.

Target Professional: Licensed Physiotherapists (BPT/MPT), Sports Medicine Specialists, and Rehabilitation Professionals.

Clinical Indications

  • Facial nerve palsy (Bell’s Palsy) rehabilitation via motor-point stimulation
  • Re-education of innervated muscles post-surgery or cast removal
  • Maintenance of denervated muscle properties during nerve regeneration
  • Diagnostic Strength-Duration (S-D) curve nerve plotting

Absolute Contraindications

  • Active cardiac pacemakers or implanted electronic devices (for electro-modalities)
  • First trimester pregnancy (direct application)
  • Active neoplastic areas or malignancy
  • Severe deep vein thrombosis (DVT)
  • Application across the thorax or heart
  • Trans-cerebral application

Clinical Precautions

  • Monitor skin integrity and patient comfort during and after treatment
  • Verify dosage parameters prior to therapy delivery
  • Avoid usage on open wounds or infected skin
  • Verify galvanic polarity (anode vs cathode) before treatment
  • Use lowest effective intensity for facial nerve re-education

Scientific Evidence & Regulatory Status

Peer-Reviewed Reference Evidence

  • [1] Kahn J: Principles and Practice of Electrotherapy (Galvanic & Faradic Stimulation)
  • [2] Strength-Duration (S-D) Curve Analysis in Peripheral Nerve Injuries

Regulatory Status

CDSCO Form MD-42 Licensed Manufacturer; ISO 9001:2015 Certified Quality System.

Technical Hardware & Clinical Specifications

Manufacturer Verified Technical Parameters for PHYSIOTREX MS-10 2 Channel Electric Muscle Stimulator & Diagnostic Modality Unit for Physiotherapy (Model: MTI22448)
Brand Physiotrex (Maktrex International)
Model / SKU MTI22448
Product Classification Clinical Therapy Machinery — Diagnostic MS-10 Galvanic & Faradic Muscle Stimulator
Primary Build Material Insulated Medical ABS Enclosure + Carbon Pads & Point Electrode
Timer Configuration Built-In Treatment Timer + Adjustable Surge/Rest Controls
Power Source 220V–240V AC, 50Hz Mains Powered
Warranty Status 1-Year Comprehensive Factory Warranty
Quality Standards ISO 9001:2015 & CE Certified (Medical Directive Compliance)
Channel Count 2 Isolated Channels (4 Electrodes)
Pulse Frequency / Rate 1 Hz - 150 Hz Variable Step Control
Pulse Width / Duration 50 µs - 400 µs Microsecond Adjustable
Therapy Waveforms Asymmetrical Biphasic, Galvanic, Interrupted Galvanic, Surged Faradic
Therapy Modes Continuous, Burst (2 Hz), Pulse Width Modulation, Frequency Modulation
Operating Voltage 220V - 240V AC, 50 Hz (Mains Powered / Internal Fuse)
Output Intensity 0 - 80 mA Adjustable per Channel with Independent Knobs
Surge Duration 1 - 10 Seconds Adjustable Surge Faradic Cycle
Rest Period 1 - 10 Seconds Rest Cycle
Safety Features Zero Start Safety Interlock, Output Circuit Breaker
Factory Warranty 1-Year Comprehensive Factory Warranty
Dispatched From Central Biomedical Dispatch Facility, Shahdara, Delhi-110032
Country of Origin India