Physiotrex Logo - Maktrex International
PHYSIOTREX Clinical Physiotherapy Equipment
Direct Factory Support: +91-7053005400 / +91-8851447406
Physiotrex IFT Machine for Physiotherapy – 65 Programs Interferential Therapy Unit with 1 Year Warranty - Physiotrex Clinical Equipment
SKU: MTI44813 • Electrotherapy

Physiotrex IFT Machine for Physiotherapy – 65 Programs Interferential Therapy Unit with 1 Year Warranty

Professional clinical electrotherapy modality

₹5,500 ₹12,500 Save 56%
In Stock • Inclusive of GST Free Pan-India Insured Freight • 1-Year Comprehensive Replacement Warranty

Availability: In Stock — Ready for Dispatch

Dispatch Facility: Shahdara, Delhi-110032 (Dispatches within 24-48 hours)

Warranty: 1-Year Comprehensive Factory Replacement & On-Site Support

Professional Physiotrex IFT Machine For Physiotherapy 65 Program (Interferential Therapy) for clinical physiotherapy.
Order Direct • Add to Cart / Hotline More in Electrotherapy
Regulated Medical Device (YMYL Compliant) CDSCO Form MD-42 Licensed
  • Quality Management: ISO 9001:2015 Certified System (Certificate No. 24EQCN62)
  • Safety Directives: European CE Medical Electrical Safety Compliant (CE-16198)
  • Manufacturing Origin: Direct from Maktrex International engineering facility, Shahdara, Delhi-110032
  • Direct Warranty: 1-Year Comprehensive Factory Replacement & Calibration Guarantee
  • Practitioner Advisory: Medically reviewed for clinical physiotherapy & hospital rehabilitation workflows

Product Overview & Clinical Applications

The Physiotrex IFT Machine for Physiotherapy with 65 Programs is an interferential therapy device designed for use in physiotherapy clinics, rehabilitation centres, hospitals, and professional therapy settings. Featuring 65 programs, as specified for this model, it is designed to support a range of interferential therapy applications, subject to the available program settings and manufacturer's specifications. Interferential therapy (IFT) is an electrotherapy modality that uses medium-frequency electrical currents to stimulate targeted areas of the body. When clinically appropriate, IFT may be incorporated into physiotherapy treatment plans to help manage certain types of pain and support rehabilitation. The Physiotrex Interferential Therapy Machine is an option for physiotherapists looking for electrotherapy equipment for their clinical practice. Its 65-program configuration can provide access to different preset treatment options, depending on how the manufacturer has designed the program library. Healthcare professionals should select suitable settings according to the patient's condition, treatment goals, and device instructions. This IFT machine for physiotherapy can be considered for use in professional rehabilitation environments where interferential therapy forms part of a broader treatment approach. It may complement therapeutic exercises and other physiotherapy interventions when recommended by a qualified healthcare professional. Designed for clinical physiotherapy applications, the Physiotrex IFT machine can be a useful addition to a rehabilitation equipment setup. Before purchase, customers should confirm the device's channel configuration, program descriptions, output parameters, intensity controls, treatment timer, electrode accessories, and other technical details with the supplier. Whether you are equipping a new physiotherapy clinic or upgrading your existing electrotherapy equipment, the Physiotrex IFT Machine with 65 Programs is a product option for facilities offering interferential therapy. For safe operation, follow the manufacturer's instructions and ensure treatment is provided by appropriately trained personnel. Patient suitability and contraindications should be assessed before use.

Clinical Safety Guidelines & Absolute Contraindications

This medical rehabilitation modality must be configured and administered under the clinical guidance of a licensed physiotherapist (BPT/MPT) or medical specialist.

  • Contraindications: Patients with active cardiac pacemakers, implanted cardioverter defibrillators (ICD), or active deep vein thrombosis (DVT).
  • Precautions: Avoid direct application across the carotid sinus, active neoplastic/malignant areas, or during first-trimester pregnancy without obstetric clearance.
  • Dosage Titration: Always start electrical or acoustic output at zero and increase according to verified clinical dosage protocols.

Key Clinical Features

  • Brand: Physiotrex
  • Product Type: Interferential therapy (IFT) machine
  • Primary Application: Interferential electrotherapy for appropriate physiotherapy treatments
  • Program Count: 65 programs, as specified for the product
  • Preset Treatment Options: Program availability and functions should be verified with the manufacturer
  • Physiotherapy Applications: Intended for use in appropriate clinical electrotherapy settings
  • Rehabilitation Support: May be incorporated into selected pain management and rehabilitation plans
  • Professional Use: Suitable for consideration by physiotherapists and rehabilitation professionals
  • Clinic Applications: Relevant to physiotherapy clinics, hospitals, and rehabilitation centres
  • Treatment Customisation: Confirm available modes, intensity controls, output settings, and program parameters
  • Safety: Use according to the manufacturer's instructions and qualified clinical guidance
  • Specification Check: Verify channels, accessories, warranty, and technical features before ordering

Clinical Governance & Medical Compliance

Intended Use & Target User

Four-pole and two-pole interferential current therapy utilizing medium-frequency carrier waves (2 kHz / 4 kHz) to produce low-frequency beat currents deep in muscle tissues for pain relief and edema resorption.

Target Professional: Licensed Physiotherapists (BPT/MPT), Sports Medicine Specialists, and Rehabilitation Professionals.

Clinical Indications

  • Deep-seated joint and spinal pain (Spondylosis, Osteoarthritis)
  • Reduction of post-traumatic and post-surgical edema
  • Deep muscle spasm relaxation and localized circulation enhancement

Absolute Contraindications

  • Active cardiac pacemakers or implanted electronic devices (for electro-modalities)
  • First trimester pregnancy (direct application)
  • Active neoplastic areas or malignancy
  • Severe deep vein thrombosis (DVT)
  • Application across the thorax or heart
  • Trans-cerebral application

Clinical Precautions

  • Monitor skin integrity and patient comfort during and after treatment
  • Verify dosage parameters prior to therapy delivery
  • Avoid usage on open wounds or infected skin
  • Ensure generous conductive gel application to silicone pads
  • Verify zero-start before initiating current

Scientific Evidence & Regulatory Status

Peer-Reviewed Reference Evidence

  • [1] Clinical Evidence for Interferential Current in Musculoskeletal Pain (Physiopedia)
  • [2] Ward AR: Electrical Stimulation Using Medium-Frequency Currents

Regulatory Status

CDSCO Form MD-42 Licensed Manufacturer; ISO 9001:2015 Certified Quality System.

Technical Hardware & Clinical Specifications

Manufacturer Verified Technical Parameters for Physiotrex IFT Machine for Physiotherapy – 65 Programs Interferential Therapy Unit with 1 Year Warranty (Model: MTI44813)
Brand Physiotrex (Maktrex International)
Model / SKU MTI44813
Product Classification Clinical Therapy Machinery — 65-Program 4 kHz Medium-Frequency IFT Console
Primary Build Material Flame-Retardant Medical ABS Housing + FR4 SMD PCB & Carbon Pads
Timer Configuration Digital Microprocessor Timer (1–60 Min Auto Cut-Off)
Power Source 220V–240V AC, 50Hz Mains Powered
Warranty Status 1-Year Comprehensive Factory Warranty
Quality Standards ISO 9001:2015 & CE Certified (Medical Directive Compliance)
Carrier Frequency 2 kHz / 4 kHz High-Stability Crystal Quartz
Base Frequency 0 - 150 Hz Continuously Adjustable
Sweep Frequency 0 - 100 Hz / 0 - 150 Hz Programmable
Channel Count 2 Channels / 4-Pole Vector Output
Operating Voltage 220V - 240V AC, 50/60 Hz with Surge Protection
Output Modes 4-Pole Vector 45°, 4-Pole Vector 90°, 4-Pole Classical, 2-Pole Premodulated
Peak Output Current 0 - 100 mA Peak-to-Peak into 500 Ω Load
Therapy Programs Microprocessor Controlled Clinical Protocols
Treatment Timer 0 - 60 Minutes with Digital Auto-Cutoff & Buzzer
Display Interface Microprocessor Digital LCD / Backlit Display
Model MTI44813
Factory Warranty 1-Year Comprehensive Factory Warranty
Dispatched From Central Biomedical Dispatch Facility, Shahdara, Delhi-110032
Country of Origin India

Related Electrotherapy Equipment