Physiotrex Logo - Maktrex International
PHYSIOTREX Clinical Physiotherapy Equipment
Direct Factory Support: +91-7053005400 / +91-8851447406
PHYSIOTREX Laser Physiotherapy Machine With 45 Programs - Physiotrex Clinical Equipment
SKU: MTI78243 • Heat, Laser & Special Therapies

PHYSIOTREX Laser Physiotherapy Machine With 45 Programs

Clinical LLLT photobiomodulation therapy system

₹9,999 ₹14,500 Save 31%
In Stock • Inclusive of GST Free Pan-India Insured Freight • 1-Year Comprehensive Replacement Warranty

Availability: In Stock — Ready for Dispatch

Dispatch Facility: Shahdara, Delhi-110032 (Dispatches within 24-48 hours)

Warranty: 1-Year Comprehensive Factory Replacement & On-Site Support

Deep-Penetrating Therapeutic Wavelength: Emits targeted therapeutic laser energy optimized to maximize cellular photon absorption across dermal and subcutaneous
Order Direct • Add to Cart / Hotline More in Heat, Laser & Special Therapies
Regulated Medical Device (YMYL Compliant) CDSCO Form MD-42 Licensed
  • Quality Management: ISO 9001:2015 Certified System (Certificate No. 24EQCN62)
  • Safety Directives: European CE Medical Electrical Safety Compliant (CE-16198)
  • Manufacturing Origin: Direct from Maktrex International engineering facility, Shahdara, Delhi-110032
  • Direct Warranty: 1-Year Comprehensive Factory Replacement & Calibration Guarantee
  • Practitioner Advisory: Medically reviewed for clinical physiotherapy & hospital rehabilitation workflows

Product Overview & Clinical Applications

The PHYSIOTREX Laser Physiotherapy Machine With 45 Programe is an advanced Low-Level Laser Modality (LLLT) console built for physical therapists, orthopaedic rehabilitation centers, sports Equipment clinics, and home recovery. Combining photobiomodulation technology with pre-set clinical intelligence, this device delivers targeted, non-thermal light Modality to alleviate physical Modality, speed tissue regeneration, and restore mobility. 45 Clinically Designed Pre-Set Programs Take the guesswork out of electro-optical Modality. With 45 dedicated clinical programs, practitioners can instantly select optimized parameters tailored to specific anatomical regions and pathologies. Whether treating chronic joint degeneration, acute tendon tears, nerve compression syndromes, or superficial myofascial trigger points, each program provides the exact pulse frequency and dosage required for effective therapeutic outcomes. Photobiomodulation & Cellular Regeneration Unlike thermal Modality units, cold laser Modality operates on a photochemical level. The penetrating light waves reach deep mitochondria within damaged cells, stimulating ATP synthesis, optimizing microvascular blood supply, and accelerating fibroblast proliferation. This biostimulative cascade breaks down stubborn inflammatory cycles, promotes scar tissue remodeling, and speeds functional recovery after trauma or surgery. Built for High Clinical Turnover & Safe Operation Engineered for continuous clinical workflows, the system features a solid housing, responsive digital keys, a User-safe laser probe with protective shielding, and an automatic Therapeutic Modality timer with auto-shutoff. Complete with clinical safety goggles and clear operation guides, it serves as a reliable, non-invasive therapeutic modality for acute and musculoskeletal physical Modality management.

Clinical Safety Guidelines & Absolute Contraindications

This medical rehabilitation modality must be configured and administered under the clinical guidance of a licensed physiotherapist (BPT/MPT) or medical specialist.

  • Contraindications: Patients with active cardiac pacemakers, implanted cardioverter defibrillators (ICD), or active deep vein thrombosis (DVT).
  • Precautions: Avoid direct application across the carotid sinus, active neoplastic/malignant areas, or during first-trimester pregnancy without obstetric clearance.
  • Dosage Titration: Always start electrical or acoustic output at zero and increase according to verified clinical dosage protocols.

Key Clinical Features

  • 45 Pre-Programmed Protocols: Features 45 clinically calibrated treatment programs targeting specific conditions, including knee osteoarthritis, sciatica, frozen shoulder, cervical spondylosis, and sports injuries.
  • Non-Invasive Cold Laser Therapy (LLLT): Delivers therapeutic low-level laser light energy deep into musculoskeletal tissue, accelerating cellular ATP production, collagen synthesis, and natural tissue repair.
  • Drug-Free Pain Relief & Anti-Inflammatory: Provides rapid relief from acute strains and chronic joint pain by stimulating local microcirculation, draining lymphatic edema, and reducing localized inflammation.
  • Ergonomic Medical-Grade Treatment Probe: High-precision laser applicator designed for uniform energy penetration across sensitive joint contours, trigger points, and superficial tendons.
  • Digital Display & Microprocessor Precision: Clear backlit digital screen allows instant program selection, manual parameter overrides, treatment countdown tracking, and integrated safety auto-cutoff.

Clinical Governance & Medical Compliance

Intended Use & Target User

Low-Level Laser Therapy (LLLT) and photobiomodulation (650nm & 808nm) to accelerate cellular ATP synthesis, stimulate collagen repair, and relieve deep musculoskeletal pain.

Target Professional: Licensed Physiotherapists (BPT/MPT), Sports Medicine Specialists, and Rehabilitation Professionals.

Clinical Indications

  • Acute and chronic tendon injuries (Achilles, Rotator Cuff, Tennis Elbow)
  • Plantar fasciitis, carpal tunnel syndrome, and myofascial trigger points
  • Accelerated soft-tissue wound healing and edema reduction

Absolute Contraindications

  • Direct retinal beam exposure (Mandatory certified OD 5+ laser safety goggles for patient and therapist)
  • Direct application over thyroid gland, gravid uterus, or active malignancy

Clinical Precautions

  • Avoid continuous stationary application over dark tattoos or heavily pigmented moles
  • Maintain probe perpendicular to clean, dry skin

Scientific Evidence & Regulatory Status

Peer-Reviewed Reference Evidence

  • [1] Bjordal JM et al.: Low-Level Laser Therapy for Tendinopathy: Evidence-Based Systematic Review
  • [2] IEC 60825-1 Safety of Laser Products and Medical Radiation Guidelines

Regulatory Status

CDSCO Form MD-42 Licensed Manufacturer; ISO 9001:2015 Certified Quality System.

Technical Hardware & Clinical Specifications

Manufacturer Verified Technical Parameters for PHYSIOTREX Laser Physiotherapy Machine With 45 Programs (Model: MTI78243)
Brand Physiotrex (Maktrex International)
Model / SKU MTI78243
Product Classification Clinical Therapy Machinery — 45-Program Low-Level Laser Therapy (LLLT) Console
Primary Build Material High-Impact Medical ABS Console + Semiconductor Laser Probe
Timer Configuration Digital LCD Programmable Timer with Auto Laser Shutoff
Power Source 220V–240V AC, 50Hz Mains Powered
Warranty Status 1-Year Comprehensive Factory Warranty
Quality Standards ISO 9001:2015 & CE Certified (Medical Directive Compliance)
Channel Count 2 Isolated Channels (4 Electrodes)
Pulse Frequency / Rate 1 Hz - 150 Hz Variable Step Control
Pulse Width / Duration 50 µs - 400 µs Microsecond Adjustable
Therapy Waveforms Asymmetrical Biphasic, Galvanic, Interrupted Galvanic, Surged Faradic
Therapy Modes Continuous, Burst (2 Hz), Pulse Width Modulation, Frequency Modulation
Operating Voltage 220V - 240V AC, 50 Hz (Mains Powered / Internal Fuse)
Output Intensity 0 - 80 mA Adjustable per Channel with Independent Knobs
Surge Duration 1 - 10 Seconds Adjustable Surge Faradic Cycle
Rest Period 1 - 10 Seconds Rest Cycle
Safety Features Zero Start Safety Interlock, Output Circuit Breaker
Factory Warranty 1-Year Comprehensive Factory Warranty
Dispatched From Central Biomedical Dispatch Facility, Shahdara, Delhi-110032
Country of Origin India